Schneider Electric Variable speed drive, Altivar Process ATV600, Compact System ATV660, 400/315 kW, 400 V, IP23; ATV660C40Q4X1
Variable speed drive, Altivar Process ATV600, Compact System ATV660, 400/315 kW, 400 V, IP23; ATV660C40Q4X1...
VAT-exclusive price: 4.338.042,00 |
VAT-inclusive price: 5.205.650,40 |
Variable speed drive, Altivar Process ATV600, Compact System ATV660, 400/315 kW, 400 V, IP23; ATV660C40Q4X1
Range of product | Altivar Process ATV600 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Process and utilities |
Device short name | ATV660 |
Product destination |
Asynchronous motors Synchronous motors |
Assembly style | In floor-standing enclosure compact version |
Provided equipment |
Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor |
cable entry | Bottom |
Colour of enclosure | Light grey (RAL 7035) |
IP degree of protection | IP23 conforming to IEC 61800-5-1 |
Type of cooling | Forced convection |
[Us] rated supply voltage | 380...415 V - 10...6 % |
Supply frequency | 50/60 Hz +/-5 % |
Network number of phases | 3 phases |
Overvoltage category | III |
Asynchronous motor control profile |
Variable torque standard Constant torque standard Optimized torque mode |
Synchronous motor control profile | Permanent magnet motor |
Output voltage | <= power supply voltage |
Permissible temporary current boost |
1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
Nominal switching frequency | 2.5 kHz |
Switching frequency | 2...8 kHz adjustable with derating factor |
Speed drive output frequency | 0.1…500 Hz |
Motor power kW |
400 kW for normal duty 315 kW for heavy duty |
Continuous output current |
730 A at 2.5 kHz for normal duty 590 A at 2.5 kHz for heavy duty |
Maximum transient current |
803 A during 60 s per 10 min (normal duty) 885 A during 60 s per 10 min (heavy duty) |
Line current |
681 A at 400 V (normal duty) 545 A at 400 V (heavy duty) |
Apparent power |
472 kVA at 400 V (normal duty) 378 kVA at 400 V (heavy duty) |
Maximum THDI | <43 % full load conforming to IEC 61000-3-12 |
Short-circuit protection |
Internal: 315.0 A 3 aR fuse Upstream: 800.0 A gG fuse (normal duty) Upstream: 630.0 A gG fuse (heavy duty) |
Energy efficiency ratio | 0.98 |
Power dissipation in W |
9900 W, total (normal duty) 7370 W, total (heavy duty) 1120 W, control part (normal duty) 770 W, control part (heavy duty) |
Volume of cooling air |
1740 m3/h for power 280 m3/h for control |
Noise level | 71 dB conforming to 86/188/EEC - physical agents (noise) directive |
Prospective line Isc | 50 kA for 100 ms |
Electrical connection |
Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control M12 bar for main supply M12 bar for motor |
Motor recommanded cable cross section |
3 x (3 x 120 mm²) (heavy duty) 3 x (3 x 185 mm²) (normal duty) 4 x (3 x 120 mm²) (normal duty) 4 x (3 x 95 mm²) (heavy duty) |
Width | 800 mm |
Height | 2150 mm |
Depth | 664 mm |
Net weight | 650 kg |
number of preset speeds | 16 preset speeds |
Communication port protocol |
Modbus TCP Modbus serial EtherNet/IP |
Option card |
Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module |
Safety function | STO (safe torque off), level SIL 3 for <= 100 ms |
EMC filter |
Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 150 m Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 250 m |
Motor slip compensation |
Can be suppressed Automatic whatever the load Adjustable Not available in permanent magnet motor law |
---|---|
Acceleration and deceleration ramps |
S, U or customized Linear adjustable separately from 0.01 to 9000 s |
Braking to standstill | By DC injection |
Protection type |
Motor: thermal protection Motor: safe torque off Motor: motor phase break Drive: thermal protection Drive: safe torque off Drive: overheating Drive: overcurrent (between output phases and earth) Drive: overload (output) Drive: short-circuit protection Drive: motor phase break Drive: overvoltage (DC bus) Drive: line supply overvoltage Drive: line supply undervoltage Drive: line supply phase loss Drive: overspeed Drive: break on the control circuit Drive: short-circuit protection with semi-conductor fuse (main supply) Drive: fan monitoring |
Frequency resolution |
Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
Connector type |
RJ45 (on the control block) for Modbus serial RJ45 (on the control block) for Ethernet IP/Modbus TCP |
Physical interface | 2-wire RS 485 for Modbus serial |
Transmission frame | RTU for Modbus serial |
Transmission rate |
10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
Type of polarization | No impedance for Modbus serial |
Number of addresses | 1…247 for Modbus serial |
Method of access | Slave Modbus TCP |
Supply |
External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
Local signalling | LCD display unit front door operation function, status and configuration |
Analogue input number | 3 |
Analogue input type |
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits |
Discrete input number | 8 |
Discrete input type |
DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Input compatibility |
DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Discrete input logic |
Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
Analogue output number | 2 |
Analogue output type |
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits |
Sampling duration |
2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AQ1, AQ2) - analog output |
Accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Linearity error |
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
Relay output number | 3 |
Relay output type |
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
Maximum switching current |
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Isolation | Between power and control terminals |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
---|---|
Operating position | Vertical +/- 10 degree |
Electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
Vibration resistance |
1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 |
Shock resistance |
4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3 |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
Ambient air temperature for operation |
-10…0 °C without derating (with option enclosure heating) 0…40 °C without derating 40…50 °C with derating factor |
Ambient air temperature for storage | -25…70 °C |
Operating altitude |
< 1000 m without derating 1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system |
Environmental characteristic |
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3 |
Standards |
EN/IEC 60204-1 EN/IEC 61800-2 EN/IEC 61800-3 EN/IEC 61800-5-1 |
Product certifications |
ATEX EAC C-Tick |
Marking | CE |
Similar products:
Schneider Electric Pogon promenljive brzine, Altivar Process ATV600, ATV650, 110 kV, 380 ... 440 V, IP54, prekidač za isključivanje;ATV650C11N4F
Variable speed drive, Altivar Process ATV600, ATV650, 110 kW, 380...440 V, IP54, disconnect switch
-

(Out of stock)
Price on request
Schneider Electric Pogon sa promenljivom brzinom, Altivar Process ATV600, ATV630, 200 kV, 380 ... 440 V, IP21;ATV630C20N4F
Variable speed drive, Altivar Process ATV600, ATV630, 200 kW, 380...440 V, IP21
-

(Out of stock)
2.798.908,00
Schneider Electric Pogon sa promenljivom brzinom, Altivar Process ATV600, ATV630, 315 kV, 380 ... 440 V, IP21;ATV630C31N4F
Variable speed drive, Altivar Process ATV600, ATV630, 315 kW, 380...440 V, IP21
-

(Out of stock)
3.367.141,00
Schneider Electric Pogon sa promenljivom brzinom, Altivar Process ATV600, ATV630, 250 kV, 380 ... 440 V, IP21;ATV630C25N4F
Variable speed drive, Altivar Process ATV600, ATV630, 250 kW, 380...440 V, IP21
-

(Out of stock)
3.407.363,00
Schneider Electric Variable speed drive, Altivar Process ATV600, Compact System ATV660, 710/560 kW, 400 V, IP23; ATV660C71Q4X1
Variable speed drive, Altivar Process ATV600, Compact System ATV660, 710/560 kW, 400 V, IP23; ATV660C71Q4X1
-

(Out of stock)
Price on request
Schneider Electric Variable speed drive, Altivar Process ATV600, Compact System ATV660, 800/630 kW, 400 V, IP23; ATV660C80Q4X1
Variable speed drive, Altivar Process ATV600, Compact System ATV660, 800/630 kW, 400 V, IP23; ATV660C80Q4X1
-

(Out of stock)