Circuit breaker, ComPacT NSX100M AC/DC, 40kA/240VAC, 1 pole, TMD trip unit 40A
Main
range |
ComPacT new generation |
product name |
ComPacT NSX new generation |
device short name |
NSX100M |
product or component type |
Circuit breaker |
device application |
Distribution |
poles description |
1P |
protected poles description |
1D |
[In] rated current |
40 A at 40 °C |
[Ue] rated operational voltage |
277 V AC 50/60 Hz
250 V DC 50/60 Hz |
network type |
AC
DC |
network frequency |
50/60 Hz |
suitability for isolation |
Yes conforming to EN/IEC 60947-2 |
utilisation category |
Category A |
[Icu] rated ultimate short-circuit breaking capacity |
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 250 V DC conforming to IEC 60947-2 |
Performance level |
M 40 kA 240 V AC |
trip unit name |
TM-D |
trip unit technology |
Thermal-magnetic |
trip unit protection functions |
LI |
control type |
Toggle |
Circuit breaker mounting mode |
Fixed |
Complementary
[Ui] rated insulation voltage |
750 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity |
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 250 V DC conforming to IEC 60947-2 |
mechanical durability |
20000 cycles |
electrical durability |
20000 cycles at 277 V In/2
10000 cycles at 277 V In |
power dissipation per pole |
5.47 W |
mounting support |
Backplate |
mounting position |
Horizontal and vertical
Flat on the back |
upside connection |
Front |
downside connection |
Front |
connection pitch |
35 mm |
protection type |
L : for overload protection (thermal)
I : for short-circuit protection (magnetic) |
trip unit rating |
40 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) |
Fixed |
[Ir] long-time protection pick-up adjustment range |
1 x In |
Long-time protection delay adjustment type tr |
Fixed |
Instantaneous protection pick-up adjustment type Ii |
Fixed |
[Ii] instantaneous protection pick-up adjustment range |
500 A |
earth-leakage protection |
Without |
Width (W) |
35 mm |
Height (H) |
161 mm |
Depth (D) |
86 mm |
net weight |
0.7 kg |
Environment
standards |
EN/IEC 60947 |
product certifications |
CCC
EAC
Marine |
overvoltage category |
Class II |
electrical shock protection class |
Class II |
pollution degree |
3 conforming to IEC 60664-1 |
IP degree of protection |
IP40 conforming to IEC 60529 |
IK degree of protection |
IK07 conforming to IEC 62262 |
ambient air temperature for operation |
-25…70 °C |
ambient air temperature for storage |
-50…85 °C |
relative humidity |
0…95 % |
operating altitude |
0...2000 m without derating
2000 m...5000 m with derating |
Packing Units
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Weight |
731.0 g |
Package 1 Height |
4.1 cm |
Package 1 width |
12.9 cm |
Package 1 Length |
17.3 cm |
Unit Type of Package 2 |
S03 |
Number of Units in Package 2 |
12 |
Package 2 Weight |
9.21 kg |
Package 2 Height |
30.0 cm |
Package 2 width |
30.0 cm |
Package 2 Length |
40.0 cm |
Main
range |
ComPacT new generation |
product name |
ComPacT NSX new generation |
device short name |
NSX100M |
product or component type |
Circuit breaker |
device application |
Distribution |
poles description |
1P |
protected poles description |
1D |
[In] rated current |
40 A at 40 °C |
[Ue] rated operational voltage |
277 V AC 50/60 Hz
250 V DC 50/60 Hz |
network type |
AC
DC |
network frequency |
50/60 Hz |
suitability for isolation |
Yes conforming to EN/IEC 60947-2 |
utilisation category |
Category A |
[Icu] rated ultimate short-circuit breaking capacity |
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 250 V DC conforming to IEC 60947-2 |
Performance level |
M 40 kA 240 V AC |
trip unit name |
TM-D |
trip unit technology |
Thermal-magnetic |
trip unit protection functions |
LI |
control type |
Toggle |
Circuit breaker mounting mode |
Fixed |
Complementary
[Ui] rated insulation voltage |
750 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity |
Similar products:
Circuit breaker, ComPacT NSX100M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 16A
-
 (Out of stock)
Circuit breaker, ComPacT NSX100S AC/DC, 70kA/415VAC, 2 poles, TMD trip unit 20A
-
 (Out of stock)
Earth-leakage add-on protection module VigiPacT, ComPacT NSX 400/630, 440VAC to 550VAC, 30mA to 30A, 3 poles
-
 (Out of stock)
Circuit breaker, ComPacT NSX500 DC PV, 10kA/1000VDC, 4 poles, TM-DC PV trip unit 500A
-
 (Out of stock)
Circuit breaker, ComPacT NSX400F DC, 36kA/750VDC, 3 poles, TM-DC trip unit 400A
-
 (Out of stock)
Circuit breaker, ComPacT NSX400S DC, 100kA/750VDC, 3 poles, TM-DC trip unit 320A
-
 (Out of stock)
Compare products
Remove all products
|